[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: PHREEQC problem



Thank you very much for your co-operation,

greetings, Jeroen

-----Original Message-----
From: David L Parkhurst [mailto:dlpark@xxxxxxxx]
Sent: dinsdag 18 juni 2002 16:20
To: Hanssen, Jeroen
In-Reply-To: <7153013F93AFD511BF0200508B2C561D4EF192@xxxxx>
Subject: Re: PHREEQC problem



> when I am modeling exchange sites and I have an input of  4.14e-3 moles
exchanger, how is it possible that I obtain
X- = 5.22E+00 moles?

I don't know,  X- is not normally printed. If the program failed to
converge, you could have some strange answers, but if the calculation
succeeded, then my experience is that mole balance is correct.

Send me your input file and I will take a look.

David


David Parkhurst (dlpark@xxxxxxxx)
U.S. Geological Survey
Box 25046, MS 413
Denver Federal Center
Denver, CO 80225

Project web page: https://wwwbrr.cr.usgs.gov/projects/GWC_coupled


Attachment: 10
Description: Binary data



Project Home Page
Complete Water Resources Division Software
USGS Home Page
Water Resources Division Home Page
NRP Home Page
Help Page
USGS Privacy Statement       

Please note that some U.S. Geological Survey (USGS) information accessed through this page may be preliminary in nature and presented prior to final review and approval by the Director of the USGS. This information is provided with the understanding that it is not guaranteed to be correct or complete and conclusions drawn from such information are the sole responsibility of the user.

Any use of trade, product, or firm names in this publication is for descriptive purposes only and does not imply endorsement by the U.S. Government. 


The URL of this page is: https://wwwbrr.cr.usgs.gov/projects/GWC_coupled/phreeqc/mail/msg00011.html
Email:dlpark@usgs.gov
Last modified: $Date: 2005-09-13 21:04:21 -0600 (Tue, 13 Sep 2005) $
Visitor number [an error occurred while processing this directive] since Jan 22, 1998.