> Sorry to bother you (again!), but I wonder if you could confirm something as it could potentially save me a lot of time. Is it correct that 'selected output files' can only be generated for initial solution data and forward modelling solutions, and not inverse modelling? I need to collate my inverse model solutions (phase transfers), which could be very time consuming from the text file output. No, it is not correct for PHREEQC version 2. If you put a SELECTED_OUTPUT data block in the input file (in the simulation with INVERSE_MODELING or before), the inverse results are printed to the selected-output file. I just checked and I think it may put some unwanted headings in the file, but the inverse results are there. David David Parkhurst (dlpark@xxxxxxxx) U.S. Geological Survey Box 25046, MS 413 Denver Federal Center Denver, CO 80225
Please note that some U.S. Geological Survey (USGS) information accessed through this page may be preliminary in nature and presented prior to final review and approval by the Director of the USGS. This information is provided with the understanding that it is not guaranteed to be correct or complete and conclusions drawn from such information are the sole responsibility of the user.