> Unintentionally I had left a 1 (forgot to edit it) for the -HDF_chemistry PRINT_FREQUENCY, though my intention was to set a -delta_time to 5 seconds (except for the first 10 seconds). What happened is that PHAST chose to use 1 second as -delta_time. In principle the safe choice in terms of not missing anything - but it did increase the simulation time considerably and it also meant that the output was rather large. That is a "feature", not a bug. It is the way the print control was designed; the idea was that if you have 10 second time steps and want a printout after 25 seconds, the step size would be adjusted to match the desired print frequency. I suppose we could put out a warning that a print frequency is smaller than the step size. Thanks, David David Parkhurst (dlpark@xxxxxxxx) U.S. Geological Survey Box 25046, MS 413 Denver Federal Center Denver, CO 80225 Project web page: https://wwwbrr.cr.usgs.gov/projects/GWC_coupled
Please note that some U.S. Geological Survey (USGS) information accessed through this page may be preliminary in nature and presented prior to final review and approval by the Director of the USGS. This information is provided with the understanding that it is not guaranteed to be correct or complete and conclusions drawn from such information are the sole responsibility of the user.