> I used example from your manual to do invers modeling. But the program still give me error about uncertanity . I noticed charge balance is high. The default units are mmol/kgw. I suspect that your data are a mixture of mg/L and ug/L. You need to define the units properly. David David Parkhurst (dlpark@xxxxxxxx) U.S. Geological Survey Box 25046, MS 413 Denver Federal Center Denver, CO 80225 Project web page: https://wwwbrr.cr.usgs.gov/projects/GWC_coupled
Please note that some U.S. Geological Survey (USGS) information accessed through this page may be preliminary in nature and presented prior to final review and approval by the Director of the USGS. This information is provided with the understanding that it is not guaranteed to be correct or complete and conclusions drawn from such information are the sole responsibility of the user.