Dave,
Is this normal or OK?
When I try to equilibrate Hematite (Fe2O3) in pure
water (pH=7, temp=25) using EQUILIBRIUM_PHASES data block, I get the following
messages:
WARNING: Maximum iterations exceeded, 100 Numerical method failed with this set of convergence parameters. WARNING: Trying smaller step size, pe step size 10, 5 ... WARNING: Maximum iterations exceeded, 200 Numerical method failed with this set of convergence parameters. WARNING: Trying diagonal scaling ... I get input errors when I try to do multiple reactions in NaOH solutions, but runs fine with HCl. What's going on?
...Jim.... |
Please note that some U.S. Geological Survey (USGS) information accessed through this page may be preliminary in nature and presented prior to final review and approval by the Director of the USGS. This information is provided with the understanding that it is not guaranteed to be correct or complete and conclusions drawn from such information are the sole responsibility of the user.